The 1075 combines harvester's electronic pump is produced in France, due to circuit and oil quality problems, there will be no fuel failure.

a. Circuit failure If the electronic pump does not respond after turning on the power switch, remove the electronic pump and connect its positive and negative wires to the positive and negative terminals of the battery respectively. If the electronic pump works, it indicates that there is a problem with the circuit. Should check the line; If there is no reaction of the electronic fuel pump, indicating the internal pump electronic pump fault, the electronic pump should be replaced.

b. oil fault If diesel is too dirty, the circuit is switched on, the electronic pump only issued a sound or continuous sound but very weak, this time should be disassembled electronic pump, remove the internal pump oil components, carried out in diesel fuel Clean, reload can be.