Pneumatic diaphragm pump working conditions are strong, for example, in the poor site of the center, such as construction sites, industrial and mining wastewater discharge, due to the impurities in the sewage and more complex composition, the pipeline easy to infarction, so the electric pump To form a high load environment, the motor heat vulnerable. Pneumatic diaphragm pump through the particles and adjustable flow, the initiative to stop the pipeline when the infarct. Because of its strong advantages, the installation of pneumatic diaphragm pump and matters needing attention is very necessary. Pneumatic diaphragm pump installation and precautions First, the pneumatic diaphragm pump specific installation process: 1, the diaphragm pump before the operation check: diaphragm pump work, prosecution of all ** fixtures to prevent relaxation, tighten the loose place to avoid leakage, with the pump The method described in the attached card is fixed. 2, diaphragm pump intake and start: start, the air valve open about 1/2 to 3/4 laps. After the pump is started, open the air valve to increase air flow to achieve the required flow rate. 3, pneumatic diaphragm pump After use: If used to transport easily curable substances, in order to prevent damage to the pump, thoroughly clean the pump after each use. Second, the installation of pneumatic diaphragm pump Note: 1, the suction pipe and the discharge pipe diameter configuration: (1) suction pipe diameter of not less than the pump inlet port diameter, such as the delivery of high viscosity fluid, the suction pipe diameter is preferably greater than Pump inlet diameter. Suction piping on the inlet side must be durable and free of wrinkles to create a high vacuum condition. (2) The diameter of the outlet pipe should be at least equal to the outlet diameter or slightly larger to reduce the friction loss. All piping and fittings must be leak-tight or pump self-priming will be reduced. 2, the location of the diaphragm pump installation, height, piping layout, gas supply and other matters: Pneumatic diaphragm pump installation: If ignore the installation details, a long period of careful planning, research and selection will still result in poor pumping effect and affect the pump The service life. (1) Location: Noise, safety and other logic often require that the equipment be installed. Parallel installation with conflicting requirements may result in blockage in the area of use, affecting the installation of other pumps. (2) Use: First, the location of the pump must be easy to use, so that maintenance personnel will facilitate routine inspection and commissioning. (3) Air supply: Each pump should have a vent pipe, and the vent pipe should be able to provide enough air to achieve the desired pump flow. Air pressure according to different pumping needs, but not more than 7BAR. (4) Installation height: Please take full account of pump self-absorption capacity to avoid self-absorption to reduce the problem. (5) Piping: The pump position can not be finalized until after considering each possible location of the piping problem. The use of such products as pneumatic diaphragm pumps needs more attention, but the preparation of these matters can provide good protection for the use of the products. As its position in the pump industry continues to improve, its research is even more important.
Hi-Vis Cap
Hi-Vis Cap,Reflective Safety Clothing,Protective Apparel ,Reflective Material
Reflective Safety ClothingCo., Ltd. , http://www.nbsafetyvest.com
没有评论:
发表评论