Vertical pipe centrifugal pump and horizontal pipe centrifugal pump eight are the most common misunderstandings are: high lift and low head Zhang Guan Li Dai, excessive elbow, etc., as follows: Vertical pipeline centrifugal pump and horizontal Pipeline centrifugal pump eight most common misunderstanding what? First, the pipeline centrifugal pump pipe does not match Some pipeline centrifugal pump users think this can improve the actual lift, in fact, the actual head of the pump = total head ~ loss of head. When the pump model is determined, the total head is a certain; loss head mainly from the pipeline resistance, the smaller the diameter of the pipe is obviously the greater the resistance, so the loss of lift the greater, so reducing the diameter, the actual pump not only can not increase the actual lift , But will be reduced, resulting in reduced pump efficiency. Similarly, when a small diameter pump with a large water pipe pumping, it will not reduce the actual lift of the pump, but will reduce the resistance due to pipelines to reduce the loss of lift, so that the actual lift has improved. However, there are also some organic hands who think that when using a large pipe for pump with small diameter, it will inevitably greatly increase the motor load. After the pipe diameter increases, the pressure in the water pipe will greatly increase the pressure on the pump impeller, which will greatly increase the motor load. As everyone knows, the size of the liquid pressure is only related to the level of head, and the size of the cross-sectional area of the water has nothing to do. As long as the lift is certain, the pump impeller size unchanged, no matter how much diameter, the role of the pressure on the impeller is certain. Only the diameter increases, the flow resistance will be reduced, leaving an increase in flow, power consumption also have an appropriate increase. However, as long as the rated head range, no matter how to increase the diameter of the pump are working, and can also reduce the pipeline loss, improve pump efficiency. Second, high-lift pump for low-lift pumping Some pipe centrifugal pump users think pumping lower head, the smaller the motor load. Misleading in this misunderstanding, the purchase of pumps, the pump is often elected head high. In fact, for centrifugal pumps, when the pump model is determined, the size of the power consumption is proportional to the actual flow of the pump. The pump flow will increase with the head decreases, so the higher the head, the smaller the flow, the smaller the power consumption. On the contrary, the lower head, the greater the flow, the greater the power consumption. Therefore, in order to prevent motor overload, the actual requirements of the actual pumping pump head lift of not less than 60% of the nominal lift. Therefore, when the high lift for low lift pumping, the motor is prone to overload and fever, severe motor burn. In case of emergency use, a gate valve (or a small outlet with wooden objects) must be installed on the outlet pipe to reduce the flow rate and prevent the motor from overload. Pay attention to the motor temperature rise, if it is found that the motor overheating, should promptly close the outlet flow or shutdown. This is also prone to misunderstandings, some people think plugging the outlet, forced to reduce the flow, will increase the motor load. In fact, on the contrary, the regular high-power centrifugal pump drainage pipe units are equipped with gate valve, in order to reduce the motor load when the unit starts, the gate valve should be closed before the motor starts and then gradually open the gate is the truth. Third, the pipe centrifugal pump inlet pipe elbow and more if the inlet pipe in the use of more elbows, will increase the local resistance to water flow. And bend should be turned in the vertical direction, not allowed to turn in the horizontal direction, so as to avoid the accumulation of air. Fourth, the installation of water pipes, the level of horizontal or upturned to do so will make the air intake pipe to gather air, reduce the vacuum degree of water pipes and pumps, so that pump suction head lift to reduce the amount of water. The correct approach is: the horizontal section should be slightly tilted to the direction of the water source, should not level, but not up tilt. Fifth, the pipeline centrifugal pump inlet connected directly with the elbow This will make the water flow through the elbow into the impeller uneven distribution. When the inlet pipe diameter is larger than the inlet of the pump, eccentric reducer should be installed. Eccentric reducer plane part to be installed in the above, bevel part installed below. Otherwise, gather air, reduce the amount of water or pumping out of water, and a percussion sound. If the inlet pipe and pump inlet diameter equal, should be in the pump inlet and elbow plus a straight tube, straight pipe length of not less than 2 to 3 times the diameter of the pipe. Sixth, the pipeline centrifugal pump outlet pipe in the pool above the normal water level if the water outlet above the normal water level, although the increase in the pump head, but reduces the flow. As a result of the terrain conditions, the outlet must be above the water level out of the pool, you should install the elbow and short tube in the nozzle to make the water pipe siphon, reducing the height of the outlet. Seven, the intake pipe inlet position is not ① intake pipe inlet into the pool bottom and pool wall distance is less than the inlet diameter. If the bottom sediment and other dirt, the inlet from the bottom of the pool is less than 1.5 times the diameter, it will cause poor pumping or sucked into the sediment debris, plug the inlet. ② inlet pipe inlet water depth is not enough, it will cause water vortex around the inlet pipe, affecting the water, reducing the amount of water. The correct installation method is: small and medium-sized pumps into the water depth of not less than 300 ~ 600mm, large pumps shall not be less than 600 ~ 1000mm. Eight, set the end of the valve, the next section of the inlet pipe is not vertical Such as installation, the valve can not be closed on their own, resulting in leakage. The correct installation method is: equipped with a valve at the end of the inlet pipe, the next section is best vertical. As a result of the terrain conditions can not be vertical installation, the water pipe axis and the horizontal angle should be 60 ° or more. Pipeline centrifugal pump is the most widely used in all fields, the most widely used pump, pharmaceutical users understand the pipe centrifugal pump eight errors, try to avoid the above. Shanghai Sunshine Pump is a professional manufacturer of pipeline centrifugal pump has a wealth of production experience and improve the testing equipment, so as to ensure product quality and stability, reliability, long life and other advantages. 【Editor's note】 Asian pump network is willing to more than vertical pipe centrifugal pump and horizontal pipe centrifugal pump with pump guide can really solve the common pain points for the first time users. Industrial Internet (Xiamen) Technology Co., Ltd. Asia Pump Network (CEO QQ / WeChat:) Editor: Spring (QQ / Wechat:) http://beng.liuti.cn/ (Service Hotline:)
Biodegradable Straw (PLA)
Disposable Straw,Individual Straw,Paper Straws
Plastic Products,Cups Co., Ltd. , http://www.nstableware.com
没有评论:
发表评论