Application of PLC in fire pump

Application of PLC in fire pump: At present, high-rise buildings are abound in various cities. In order to prevent accidental fire, high-rise buildings are generally equipped with fire pump. Although norms, rules and regulations clearly require fire-fighting facilities, equipment should be regularly maintained. However, the current fire pump can not do regular test run, over time will lead to the pump, the end of the valve and one-way valve stuck dead rust, it often appears in the event of a fire equipment can not fully play the role of the situation, resulting in not Due to the loss, for this "civil building water fire extinguishing system design rules" provides for high buildings, a class of high-rise public buildings fire pump should set the self-test device. National Fire Services Department in 1999 below requires that all fire-fighting equipment must have a self-test function, fire control equipment must be automatically activated within 15 days once to prevent corrosion of the pump rust. Another revision in the "Code for Fire Protection of Buildings" also proposed: fire water supply equipment must have automatic inspection function. Usually the old equipment adopts the backward relay contactor control mode, the intermediate relay and the timing relay are too many, the function is less, the line is complicated, the contact is many, cause the trouble more reliability is bad, the maintenance is difficult. We use Beijing Kaidian Automation Technology Co., Ltd. programmable logic controller (PLC) of the fire pump control to achieve regular standby pump test run, fire fighting automatically start, so as to effectively eliminate the fire pump can not be the key moment Used situation. The reason why PLC has vitality lies in its input and output terminals are closer to the field devices, without adding too many intermediate components or need more interfaces, high reliability, anti-interference ability, easy maintenance, no hardware adjustments Components, low price and long life. This saves users time and costs, but also can easily be expanded according to different needs. 1. Automatic patrol function Automatic (patrol switch on) Under the condition of no fire fighting water supply, the first pump starts (star) for 5-30 seconds (start time is determined by the equipment), run (triangle) 10 Seconds, standstill standby 120-360 hours (five - fifteen days). If there is no fire fighting water on standby, the second pump starts 5-30 seconds, runs for 10 seconds and stands on standby for 120-360 hours, so that it cycles cyclically (inspection cycle: from hours to hundreds of hours Select) control cabinet and with overpressure protection, from a reliable point of view, to set the pressure relief valve. In the fire water demand, the pump immediately start automatically, pressurized water supply, give full play to its role. If in order to avoid damage to the pipe network due to pressure increase, we increase the electromagnetic valve in the pipe network, open the electromagnetic valve to open the pump pressure relief inspection, inspection pump start working time is also delayed to 10 minutes. 2. Kai pump mode and sequence In the case of automatic start of multiple pumps, in order to avoid the same time put into the water pump caused too much impact on the power grid, the pump is a Taiwan 20 seconds apart from the start. Automatically start and patrol Kai pump, first issued three sound and light alarm (alarm 2 seconds interval 2 seconds), and then start the pump. The backup pump should be able to be put into operation automatically (with a delay of 10 seconds) when there is a malfunction in the working pump of the device (overload and short-circuit signals) because of the importance of the fire pump The backup pump is operated without overload protection. Starting pump frequency direct start, start from the lotus buck, Y- △ buck start, thyristor soft-start control, constant frequency control and other means to meet different requirements. For example: 2 pump start sequence 1 with 2 standby, 2 with 1 standby, two ways; 3 pump start sequence 1, 2 with 3 spare, 2,3 with 1 spare, 3,1 with 2 prepared, three ways and so on. 3. Control Panel Display In the design of automatic control system, we designed the fault display alarm system. When the device starts up, the indicator blinks at a frequency of 1 Hz. The corresponding indicator light is on in normal operation. The fault indicator is always on when the device is faulty. In order to prevent the lamp bulb damage can not correctly reflect the work of equipment, specially set the fault test button, the system is running at any time press any button 3s, all the lights should be all lit, if there are instructions, etc. do not light at that time that the light Has been bad, should be replaced immediately, the button is still reset after the indicator shows the working status of the device.

Precision Steel Tube

Precision Steel Tube,High Precision Tube,Precision Seamless Tube ,Precision Stainless Steel Tubing

Liaocheng Xinglong Seamless Tube Manufacturing Co., Ltd. , https://www.lcxlpipe.com

没有评论:

发表评论