1. First check everywhere bolts loose, the power cord and the plug is intact, the motor insulation resistance should be greater than 2 megohm.
2 In order to prevent electric shock accidents, it is necessary to install the corresponding safety measures such as earth leakage circuit breaker or electric shock safety device, and to conduct reliable grounding
3. The working voltage of the pump should be used within the range of +5% and -12% of the rated voltage, otherwise the service life of the motor will be shortened or burned out. Electric pump as far away from the power supply, power transmission line should be appropriate bold, otherwise it will use the voltage drop and can not run.
4 Close the power switch, the pump idle for about 2 minutes to see the start, the operation is normal, the steering is correct.
5 Fix the pump body with steel pipe or rubber tube (must not be too soft to avoid suction), connect the inlet and the bottom valve. The bottom valve must be placed perpendicular to the horizontal surface and above the water bottom 30cm to avoid sucking the sediment.
6. Clean water centrifugal pump to use and automatically suck the pump for the first time before use, it is necessary to fill the tank water, electricity can not automatically after a few seconds out of water, the future does not require irrigation.
7. Since the pump and automatic self-priming clear water pump tube for the first time before use, it is necessary to fill the water tank filled with water, electricity can not automatically after a few seconds out of water, the future does not require irrigation.
8. Use, the motor should be kept dry, pay attention to the water level down, the bottom valve can not be exposed outside the water. When the temperature is below 4 ○ C. Antifreeze should be done, so as not to freeze the pump body.
9 If it is not used for a period of time, drain the water in the pump (self-priming pump and automatic pump to drain the water in the water tank), scrub the main parts clean, apply anti-rust oil and keep it in a ventilated and dry place for future use.
Ceiling Type Air Handling Unit
Air flow 1,000m3/h-30,000m3/h, Coil type 4rows/6rows/8rows
Characteristics:
1.Air handing unit applies colorful steel and galvanized panel as its interior and exterior panel. Inner stuff is the high density polyurethane foam,double pillar and tenon structure that ensures the strength of the unit and low air leakage.
2.High efficiency and low resistance nylon filter that reduce the power consumption obviously. Easy cleaning and simple operation; at the same time, higher level panel filter is optional too.
3.Coil applies pure and seamless copper tube and hydrophilic aluminum fin. Copper tube is under 12MPa water pressure expanding that can adapt to all kind of high pressure and no leakage, as well as ensure the lowest contact thermal resistance and highest heat transfer efficiency.
4.All fans in the unit are selected by professional software to ensure the best condition. Minimize the air volume and air pressure loose after meeting with the customer's requirements. Also ensure the good airflow and reduce the air duct noise.
5.Ceiling type air handling unit wish small size, low noise. It is widely applied in the comfortable Air Conditioning system such as the hostel, commercial building, office and underground railway application.
Ceiling Type Air Handling Unit
Ceiling Type Air Handling Unit,Ceiling Suspended Air Handling Units,Ceiling Vertical Type Air Handling Unit,Ceiling Concealed Type Air Handling Unit