2019年11月5日星期二

Vacuum pump performance parameters and the use of

First, the performance parameters of the vacuum pump

1, the ultimate pressure of the vacuum pump

The pump's ultimate pressure unit is Pa, which means that the pump is fitted with a standard test hood at the inlet and is operating at the specified conditions and tends to a steady minimum pressure without the introduction of normal gas service.

2, vacuum pumping speed

Pump pumping speed unit is m3 / s or l / s, is the pump equipped with a standard test cover, and the provisions of the working conditions, the flow of gas flow through the test cover and the test hood at a specified position measured equilibrium pressure Ratio. Pump pumping speed.

3, the amount of vacuum pumping

Vacuum pump pumping unit is Pa m3 / s or Pa l / s. It refers to the pump inlet gas flow.

4, the starting pressure of the vacuum pump

Vacuum pump starting pressure unit Pa, which refers to the pump start without damage and the pressure of the exhaust effect.

5, the pressure before the pump

The pressure unit of the front stage of the vacuum pump is Pa, which means the outlet pressure of the vacuum pump whose discharge pressure is lower than one atmosphere.

6, the maximum pressure before the vacuum pump

The maximum pressure in the front of the vacuum pump port is Pa, which means more pressure than the previous one that can damage the pump.

7, the maximum working pressure of the vacuum pump

Vacuum pump maximum working pressure unit is Pa, it refers to the maximum amount of suction inlet pressure. Under this pressure, the pump can work continuously without deterioration or damage.

8, compression ratio

The compression ratio is the ratio of the pump outlet pressure to the inlet pressure for a given gas.

9, Ho coefficient

The ratio of the actual pumping speed on the pumping channel area to the theoretical pumping speed calculated on the basis of molecular effusion.

10, pumping speed coefficient

The actual pumping speed of the pump is calculated as the ratio of theoretical pumping speed calculated by molecular diathermy at the pump inlet.

11, reflux rate

Pump backflow rate unit is g / cm2.s. It refers to the pump when the required conditions work, through the pump inlet unit area pump flow mass flow rate.

12, the amount of water vapor allowed

Water vapor allowable unit is kg / h, it refers to the pump under normal ambient conditions, the gas pump can be removed in continuous operation of the water vapor mass flow.

13, the maximum allowable steam inlet pressure

The maximum allowable water vapor inlet pressure unit is Pa. It refers to the maximum inlet pressure of water vapor that can be extracted by the gas-operated pump under continuous operation under normal environmental conditions.

Second, the use of vacuum pumps

As a variety of vacuum pumps have a working pressure range and starting pressure are different, so the choice of vacuum pump must meet these requirements.

Plate Flange is the most popular using flange type, DIN EN1092-1 BS4504 GOST33259-2015 SANS1123 JIS B2220 KS B1503 and ANSI B16.5 both have plate flange type, plate flange pressure for PN6 PN10 PN16 PN25 PN40, ANSI B16.5 rating class for 150 and 300, JIS B2220 and KS B1503 class for 5K 10K 16K 20K, plate flange facing type have flat face, raised face.

Plate Flange Flat Face

Full Face Flange,En1092-1 Type01 Pn16,Pn16 Flange P245Gh,Plate Flange Flat Face

Jinan Hyupshin Flanges Co., Ltd , https://www.iflange.com

没有评论:

发表评论